description abstractA radiometric method of tool-wear evaluation was investigated and evaluated by comparing the results with those obtained from visual wear measurements. A liquid scintillation technique is presented for accurately determining tool wear for cutting limes as low as 0.003 min. It is recommended that the radioactive tracer techniques of measuring tool wear be used as supplemental methods in conjunction with visual wear determination procedures rather than primary methods of evaluating machining variables.
publisherThe American Society of Mechanical Engineers (ASME)
titleStudy of the Radiometric Method and Use of the Liquid Scintillation Technique for Tool-Wear Determination
typeJournal Paper
journal volume87
journal issue1
journal titleJournal of Manufacturing Science and Engineering
identifier doi10.1115/1.3670757
journal fristpage47
journal lastpage52
identifier eissn1528-8935
keywordsWear
keywordsRadioactive tracers
keywordsMachining
keywordsMeasurement AND Cutting
treeJournal of Manufacturing Science and Engineering:;1965:;volume( 087 ):;issue: 001