description abstractWe present a model of the human cornea in order to study the changes in its shape resulting from surgical operations (e.g., radial keratotomy). A simple closed-form solution is given for a thin linearly elastic spherical shell model of the cornea. We assume axisymmetry and isotropy in the shell surface. The surgery is modeled by permitting Young’s modulus and shell thickness to depend on position. The analytical nature of the solution permits principal shell curvatures to be explicitly calculated. The model is used to in vestigate the effect of surgery on corneal flattening and the associated sensitivity to intraocular pressure changes.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalytical Model of Corneal Surgery
typeJournal Paper
journal volume113
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2891240
journal fristpage239
journal lastpage241
identifier eissn1528-8951
keywordsSurgery
keywordsCornea
keywordsShells
keywordsSpherical shells
keywordsThickness
keywordsIsotropy
keywordsShapes
keywordsPressure AND Elasticity
treeJournal of Biomechanical Engineering:;1991:;volume( 113 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record