Show simple item record

contributor authorT. M. Mulcahy
date accessioned2017-05-08T23:30:54Z
date available2017-05-08T23:30:54Z
date copyrightFebruary, 1989
date issued1989
identifier issn0094-9930
identifier otherJPVTAS-28307#25_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/105910
description abstractEccentricity of a specific slip-joint design separating two cantilevered telescoping tubes did not create any self-excited lateral vibrations that had not been observed for a concentric slip joint. In fact, the eccentricity made instabilities less likely to occur, but only marginally. Most importantly, design rules previously established to avoid instabilities for the concentric slip joint remain valid for the eccentric slip joint.
publisherThe American Society of Mechanical Engineers (ASME)
titleLeakage Flow-Induced Vibration of an Eccentric Tube-in-Tube Slip Joint
typeJournal Paper
journal volume111
journal issue1
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.3265636
journal fristpage25
journal lastpage31
identifier eissn1528-8978
keywordsDesign
keywordsFlow-induced vibrations
keywordsVibration AND Leakage
treeJournal of Pressure Vessel Technology:;1989:;volume( 111 ):;issue: 001