Show simple item record

contributor authorL. F. Waring
contributor authorD. S. Weaver
date accessioned2017-05-08T23:28:00Z
date available2017-05-08T23:28:00Z
date copyrightMay, 1988
date issued1988
identifier issn0094-9930
identifier otherJPVTAS-28301#194_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/104372
description abstractAn experimental study is reported of the effects of partial admission on the fluid elastic stability of a heat exchanger tube array. The array geometry was a parallel triangular configuration with a pitch ratio of 1.47. Tests were conducted in a wind tunnel with uniform flow over from 33 to 100 percent of single span tubes. In these experiments, the flow location was also varied from center-span to the end supports. Additionally, tests were conducted with uniform flow over one span of two and three-span tube arrays. These results are compared with theoretical predictions.
publisherThe American Society of Mechanical Engineers (ASME)
titlePartial Admission Effects on the Stability of a Heat Exchanger Tube Array
typeJournal Paper
journal volume110
journal issue2
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.3265586
journal fristpage194
journal lastpage198
identifier eissn1528-8978
keywordsStability
keywordsHeat exchangers
keywordsFlow (Dynamics)
keywordsFluids
keywordsGeometry AND Wind tunnels
treeJournal of Pressure Vessel Technology:;1988:;volume( 110 ):;issue: 002