description abstractA fully implicit three-dimensional, control-volume-based, finite difference model has been developed for predicting temperature distributions and thermal expansion in a rotating variable section cylindrical domain. Included in the model formulation is a technique for accommodating boundary conditions that are geometrically nonorthogonal with respect to the surface finite difference grid. Steady-state results applicable to hot and cold rolling processes are presented, with emphasis placed on the evaluation of selective coolant application as a means for controlling the axial distribution of radial roll thermal expansion.
publisherThe American Society of Mechanical Engineers (ASME)
titleEvaluation of Selective Coolant Application for the Control of Work Roll Thermal Expansion
typeJournal Paper
journal volume107
journal issue2
journal titleJournal of Manufacturing Science and Engineering
identifier doi10.1115/1.3185978
journal fristpage146
journal lastpage152
identifier eissn1528-8935
keywordsThermal expansion
keywordsCoolants
keywordsBoundary-value problems
keywordsSteady state AND Temperature distribution
treeJournal of Manufacturing Science and Engineering:;1985:;volume( 107 ):;issue: 002