| contributor author | A. M. Lynnworth | |
| contributor author | L. C. Lynnworth | |
| date accessioned | 2017-05-08T23:20:36Z | |
| date available | 2017-05-08T23:20:36Z | |
| date copyright | March, 1985 | |
| date issued | 1985 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-27010#44_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/100054 | |
| description abstract | In applying the ultrasonic contrapropagation method to the measurement of flow in highly attenuating fluids, or to fluids in conduits having only limited access, it is sometimes necessary to interrogate along a path other than the conventional tilted diameter or midradius chordal paths. The meter factor K, which relates the path average to the area-averaged flow velocity, is derived from Nikuradse profiles for several new paths. The results enable one to locate transducers so that for the chosen type of path, K will be (a) minimally dependent on Re, and/or (b) approximately equal to unity, or (c) represented by a simple function of Re. For smooth-wall steady flow conditions, the error in the calculated K’s is estimated as ±2 percent ± the effect due to the disturbance of Nikuradse profiles by the transducers. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Calculated Turbulent-Flow Meter Factors for Nondiametral Paths Used in Ultrasonic Flowmeters | |
| type | Journal Paper | |
| journal volume | 107 | |
| journal issue | 1 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.3242438 | |
| journal fristpage | 44 | |
| journal lastpage | 48 | |
| identifier eissn | 1528-901X | |
| keywords | Flow (Dynamics) | |
| keywords | Fluids | |
| keywords | Flowmeters | |
| keywords | Turbulence | |
| keywords | Transducers | |
| keywords | Errors AND Flow measurement | |
| tree | Journal of Fluids Engineering:;1985:;volume( 107 ):;issue: 001 | |
| contenttype | Fulltext | |