Search
Now showing items 1-1 of 1
Freezing by a Flat, Circular Surface Cryoprobe of a Tissue Phantom With an Embedded Cylindrical Heat Source Simulating a Blood Vessel
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The effects of a thermally-significant blood vessel, simulated by an embedded acrylic tube, 4.8 mm outer diameter, on the freezing field caused by a surface cryoprobe were studied experimentally ...
CSV