description abstractA laidback fan-shaped hole is commonly used due to its superior lateral film coverage. Its discharge coefficient is significantly influenced by internal crossflow owing to its complex geometrical structure. In this paper, the authors numerically investigate the flow mechanisms of the laidback fan-shaped hole under the influence of internal crossflow. The numerical simulations utilize the validated SST k–ω turbulence model, with the Reynolds number of internal crossflow ranging from 20,000 to 160,000 and the ratio of pressure ranging from 1 to 1.6. The results show that the different orientations of internal crossflow cause varying degrees of in-hole separation that led to a discrepancy in the discharge coefficient. The larger the Reynolds number of the crossflow is, the more drastic the change in the discharge coefficient. Furthermore, a comparison between the results obtained with and without internal crossflow has shown that the length of the cylindrical section is the primary factor determining the discharge coefficient of the laidback fan-shaped hole. The magnitude of the discharge coefficient depended on the extent of flow separation within the cylindrical section. Additionally, the numerical simulations obtained the discharge coefficient under a high internal crossflow Reynolds number of internal crossflow and a wall with a constant thickness and compared it with the predictions of a low-dimensional model of the discharge coefficient (based on our previous experimental data). The discrepancy between the results is within 10%, thus verifying the scalability of the low-dimensional model.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffect of the Key Geometry and Flow Parameters on Discharge Coefficient of Laidback Fan-Shaped Hole Under Coolant Crossflow Condition
typeJournal Paper
journal volume146
journal issue8
journal titleJournal of Turbomachinery
identifier doi10.1115/1.4064837
journal fristpage81006-1
journal lastpage81006-17
page17
treeJournal of Turbomachinery:;2024:;volume( 146 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record