Show simple item record

contributor authorAbbasi Bavil, Elyar
contributor authorDoyle, Matthew G.
contributor authorDebbaut, Charlotte
contributor authorWald, Rachel M.
contributor authorMertens, Luc
contributor authorForbes, Thomas L.
contributor authorAmon, Cristina H.
date accessioned2022-02-05T22:28:21Z
date available2022-02-05T22:28:21Z
date copyright12/14/2020 12:00:00 AM
date issued2020
identifier issn0148-0731
identifier otherbio_143_03_031011.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277592
description abstractFontan associated liver disease is a common complication in patients with Fontan circulation, who were born with a single functioning heart ventricle. The hepatic venous pressure gradient (HVPG) is used to assess liver health and is a surrogate measure of the pressure gradient across the entire liver (portal pressure gradient (PPG)). However, it is thought to be inaccurate in Fontan patients. The main objectives of this study were (1) to apply an existing detailed lumped parameter model (LPM) of the liver to Fontan patients using patient-specific clinical data and (2) to determine whether HVPG is a suitable measurement of PPGs in these patients. An existing LPM of the liver blood circulation was applied and tuned to simulate patient-specific liver hemodynamics. Geometries were collected from seven adult Fontan patients and used to evaluate model parameters. The model was solved and tuned using waveform measurements of flows, inlet and outlet pressures. The predicted ratio of portal to hepatic venous pressures is comparable to in vivo measurements. The results confirmed that HVPG is not suitable for Fontan patients, as it would underestimate the portal pressures gradient by a factor of 3 to 4. Our patient-specific liver model provides an estimate of the pressure drop across the liver, which differs from the clinically used metric HVPG. This work represents a first step toward models suitable to assess liver health in Fontan patients and improve its long-term management.
publisherThe American Society of Mechanical Engineers (ASME)
titleCalibration of an Electrical Analog Model of Liver Hemodynamics in Fontan Patients
typeJournal Paper
journal volume143
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4049075
journal fristpage031011-1
journal lastpage031011-12
page12
treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 003
contenttypeFulltext