    Laboratory Testing of Rheological Behavior of Water-Foamed Bitumen

    Source: Journal of Materials in Civil Engineering:;2018:;Volume ( 030 ):;issue: 008
    Author:
    You Lingyun;You Zhanping;Yang Xu;Ge Dongdong;Lv Songtao
    DOI: 10.1061/(ASCE)MT.1943-5533.0002362
    Publisher: American Society of Civil Engineers
    Abstract: From the rheological behavior of bitumen, one can understand the physical properties of water-foamed bitumen used in warm mix asphalt. Previously, rheological behaviors of water-foamed bitumen such as apparent viscosity, agitation torque, and shear rate have not been well documented. The objectives of this study are as follows: (1) evaluating the accuracy of the cup-and-bob test with a dynamic shear rheometer to investigate the rheological behavior of water-foamed bitumen, (2) analyzing the rheological behavior of water-foamed bitumen at various temperatures, and (3) proposing an optimum water content that decreases the apparent viscosity and required agitation torque of water-foamed bitumen. Bitumen with various water contents (ranging from . to 3.% bitumen content by mass) were prepared for rheological testing. The optimum water content at each of these foaming temperatures was determined based on the testing results. This study concludes that the current cup-and-bob test methods accurately describe the rheological behavior of water-foamed bitumen. Within the accepted water content range, the apparent viscosity and required agitation torque of water-foamed bitumen decrease more dramatically as water content increases.
    • Download: (1.661Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Laboratory Testing of Rheological Behavior of Water-Foamed Bitumen

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4249278
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorYou Lingyun;You Zhanping;Yang Xu;Ge Dongdong;Lv Songtao
    date accessioned2019-02-26T07:46:34Z
    date available2019-02-26T07:46:34Z
    date issued2018
    identifier other%28ASCE%29MT.1943-5533.0002362.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4249278
    description abstractFrom the rheological behavior of bitumen, one can understand the physical properties of water-foamed bitumen used in warm mix asphalt. Previously, rheological behaviors of water-foamed bitumen such as apparent viscosity, agitation torque, and shear rate have not been well documented. The objectives of this study are as follows: (1) evaluating the accuracy of the cup-and-bob test with a dynamic shear rheometer to investigate the rheological behavior of water-foamed bitumen, (2) analyzing the rheological behavior of water-foamed bitumen at various temperatures, and (3) proposing an optimum water content that decreases the apparent viscosity and required agitation torque of water-foamed bitumen. Bitumen with various water contents (ranging from . to 3.% bitumen content by mass) were prepared for rheological testing. The optimum water content at each of these foaming temperatures was determined based on the testing results. This study concludes that the current cup-and-bob test methods accurately describe the rheological behavior of water-foamed bitumen. Within the accepted water content range, the apparent viscosity and required agitation torque of water-foamed bitumen decrease more dramatically as water content increases.
    publisherAmerican Society of Civil Engineers
    titleLaboratory Testing of Rheological Behavior of Water-Foamed Bitumen
    typeJournal Paper
    journal volume30
    journal issue8
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/(ASCE)MT.1943-5533.0002362
    page4018153
    treeJournal of Materials in Civil Engineering:;2018:;Volume ( 030 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian